LoboVault Home
 

Using polymer ligand films for rapid radiochemical analyses

LoboVault

Please use this identifier to cite or link to this item: http://hdl.handle.net/1928/12596

Using polymer ligand films for rapid radiochemical analyses

Show full item record

Title: Using polymer ligand films for rapid radiochemical analyses
Author: Tulley-Cordova, Crystal L.
Subject(s): radiochemical analysis
thin film technique
radionuclides
LC Subject(s): Radiochemical analysis--Equipment and supplies.
Radioactive pollution of water--Mesurement--Equipment and supplies.
Drinking water--Analysis--Equipment and supplies.
Trace elements in water--Analysis--Equipment and supplies.
Thin films--Scientific applications.
Polymers--Scientific applications.
Ligands--Scientific applications.
Abstract: Existing procedures for radiochemical analysis of environmental samples involves extensive laboratory preparation requiring chemical separations that are time consuming, and labor intensive to remove interferences and impurities associated with the sample matrix. Technology developed in this project reduces turnaround time, labor and supplies needed to examine radionuclides in water samples. The thin film technique can be used as a screening method. A solution including an extractive ligand and polymer are used to create a thin film to concentrate radionuclides from solution. In this project, several ligands, polymers, solvents, thin film types, and extraction procedures were examined. The polymer ligand thin films were analyzed using alpha spectrometry. Using the polymer ligand thin film method decreased sample preparation time. The thin film extraction and analysis procedure allows rapid and sensitive monitoring of select actinides in tap water with the potential for use with surface and groundwater systems in the field. The thin film method is a proof of concept of polymer ligand film extracting radionuclides; we have demonstrated our capability for detection of plutonium in laboratory samples at concentrations of 2.5 x 10-1 Becquerels/Liter (Bq/L). The thin film used for extraction and collection was made using a polymer and ligand solution which was deposited and dried on a stainless planchet. The suitable combination of polymer, ligand and solvent solution included polystyrene, Dipex®, and tetrahydrofuran. After evaporation, polystyrene and Dipex® remain on the stainless steel planchet.
Date: 2011-05-10
Description: A Professional Project submitted in partial fulfillment of the requirements for the Degree of Master of Water Resources, Water Resources Program, University of New Mexico.
URI: http://hdl.handle.net/1928/12596

Files in this item

Files Size Format View Description
Tulley PP_031111.pdf 739.2Kb PDF View/Open TulleyFinal

This item appears in the following Collection(s)

Show full item record

UNM Libraries

Search LoboVault


Advanced Search

Browse

My Account