LoboVault Home
 

Lateral outflow from supercritical channels

LoboVault

Please use this identifier to cite or link to this item: http://hdl.handle.net/1928/11162

Lateral outflow from supercritical channels

Show simple item record

dc.contributor.author Bernardo, Nelson
dc.date.accessioned 2010-09-10T17:16:58Z
dc.date.available 2010-09-10T17:16:58Z
dc.date.issued 2010-09-10
dc.date.submitted July 2010
dc.identifier.uri http://hdl.handle.net/1928/11162
dc.description.abstract Stormwater pollutants caused by urban runoff are a major concern for the Albuquerque Metropolitan Arroyo Flood Control Authority (AMAFCA), and other flood control authorities, as stormwater channels eventually are discharged into natural waterways. One method of improving stormwater quality is diverting frequent storms or the first flush of less frequent storms to a structural debris filter and/or a constructed wetland prior to reentrance into the channel. The focus of this study was to develop a procedure to allow determination of laterally diverted flows of stormwater from a supercritical channel for treatment. A range of design flows were tested and evaluated for a trapezoidal channel with a lateral outflow pipe. Lateral pipe angle, pipe invert, and vane configurations were tested for outflow efficiency and to observe hydraulic effects in the main channel. A bench-top model was constructed and tested to determine which pipe invert, configuration, and pipe diameter would be used for the larger scale experiments. An 8 inch (20.32 cm) diameter pipe set across the base of the channel with a pipe invert of 50% increased the diversion ratio within the range of 15% to 100%, depending on the configuration tested. Three pipe angles, 30°, 45° and 90°, were used in the experiment with the 30° pipe diverting the highest amount of water, with 97.8% being the lowest at a Froude number of 2.71 and velocity of 2.97 ft/s (0.905 m/s), with little to no negative hydraulic effects to channel flow. A uniform and tapered vane structure at different vane angles, 35°, 40° and 45°, was added to the different pipe angles to increase the diversion ratio. A tapered vane at a 45° vane angle diverted the most water, with a diversion ratio of 97.31% being the lowest at a Froude number of 2.96 and a velocity of 3.76 ft/s (1.15 m/s), with a stable jump upstream of the vane. HEC-RAS was used to model three different pipe angles relative to the main channel axis to determine if the numerical program was able to capture the hydraulic effects observed from the physical model. The results from the program are in agreement of the adverse affects that were seen at the different pipe angles. The program was able to capture the adverse hydraulic effects, rolling waves and hydraulics jumps, in the physical model with similar upstream velocity and Froude number values. en_US
dc.language.iso en_US en_US
dc.subject Lateral outlfow en_US
dc.subject supercritical en_US
dc.subject.lcsh Storm sewers--Design and construction.
dc.subject.lcsh Diversion structures (Hydraulic engineering)--Design and construction.
dc.title Lateral outflow from supercritical channels en_US
dc.type Thesis en_US
dc.description.degree Civil Engineering en_US
dc.description.level Masters en_US
dc.description.department University of New Mexico. Dept. of Civil Engineering en_US
dc.description.advisor Coonrod, Julie
dc.description.committee-member Thomson, Bruce
dc.description.committee-member Stone, Mark


Files in this item

Files Size Format View
Bernardo.Thesis.pdf 2.766Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

UNM Libraries

Search LoboVault


Advanced Search

Browse

My Account